What are P50 and P90 scenarios?
P50 and P90 are two readings of the same production projection. P50 is the value expected to be exceeded in half of the years: the central scenario. P90 is the conservative one, expected to be exceeded 9 years out of 10. The gap between them shows how uncertain the projection is.
In 30 seconds
- P50 is exceeded in half the scenarios; P90 in nine out of ten.
- P90 is always lower than P50: it's the prudent reading.
- More uncertainty in the sun or the data pushes the two values further apart.
Why should you care?
A production projection isn't a fixed number: the sun changes from year to year. P50 and P90 show you the center and a reasonable floor.
- You know whether a production figure is the central or the prudent one.
- You see how far a bad year's energy could move from a normal one.
- You compare projects knowing which scenario each one uses.
Think of it as your commute to work
Half of the days you get there in 30 minutes or less: that's your P50. But for an important meeting you leave 40 minutes ahead, because that gets you there on time 9 days out of 10: that's your P90. Same trip, two ways to plan.
How does P50 and P90 scenarios work?
- 1
Production is simulated
Software such as PVsyst uses many years of sun data, the design and the losses to estimate annual energy.
- 2
The P50 comes out
It's the central value: half the years are expected to produce more and half less.
- 3
Uncertainty is measured
How much the sun varies between years is combined with the margin of error in the data and the model.
- 4
The P90 is calculated
That uncertainty is taken off the P50 to reach a value exceeded 9 years out of 10.
The formula
P90 ≈ P50 × (1 − 1.282 × σ)
- P50
- = annual production in the central scenario
- σ
- = combined uncertainty, as a percentage of P50
- 1.282
- = statistical factor for a 90% probability
An example with numbers
A 1 MWp system with a P50 of 1,314 MWh a year, as in the GW, MW and kWp lesson, and a combined uncertainty of 7%. Illustrative figures, unrelated to any project.
| P50 | 1,314 MWh a year |
|---|---|
| Discount (1.282 × 7%) | 9% |
| P90 (1,314 × 0.91) | 1,196 MWh a year |
| Difference | 118 MWh a year |
In 9 years out of 10, at least 1,196 MWh is expected. A very bad year can still fall below it: P90 isn't an absolute floor.
Where do you see it at Circular Urban?
Each solar project's sheet shows the estimated annual production from the design simulation. When a technical study reports scenarios, it helps to know which one a figure belongs to. It's a reference projection: real production depends on each year's weather and the project's performance.
- Each solar project's sheet, in Energy Production: Annual Production.
- Each solar project's sheet, in Risks & Mitigants.
What changes in your finances once you get it
You ask which scenario it is
Faced with a production figure, you check whether it's P50 or P90 before drawing conclusions.
You plan with a margin
You also run your numbers with the prudent scenario, so a weak year doesn't catch you off guard.
You read the gap
If P50 and P90 are far apart, the projection carries more uncertainty.
Common mistakes
- Myth
P90 is the least the project can produce.
- In reality
It's a value expected to be exceeded 9 years out of 10. In one year out of ten, production can fall below it.
- Myth
P50 means the project runs at 50% of its capacity.
- In reality
The 50 refers to probability, not capacity: it's the value exceeded in half the years.
- Myth
If a year comes in below P50, the projection was wrong.
- In reality
By definition, half the years are expected to fall below P50. What matters is the average over several years.
Test yourself
A project has a P50 of 2,000 MWh and a combined uncertainty of 5%. What is its approximate P90?
Keep learning